WINTER MODE: SET & FORGET

❄️ WINTER MODE — INSTALLER CHEAT SHEET (Controller‑Specific)

 

🔧 1. Winter Mode Activation

  • Enable Winter Mode — reduces filtration, chlorination, and heating logic
  • Confirm correct mode on display — avoid customer confusion
  • Check automation handover — ensure pump/heat sources follow controller logic

 

🔁 2. Filtration Scheduling

  • Set winter filtration hours — 2–4 hrs/day
  • Run during warmest part of day — 11am–3pm
  • Split into short cycles — improves chemical distribution

 

⚙️ 3. Pump RPM Profiles

  • Set low‑RPM winter profile — 900–1400 RPM
  • Allow auto‑RPM boost for heating — only when heating is active
  • Disable high‑RPM cleaning cycles — unless manually triggered

 

🌞 4. Solar Heating Lockout

  • Turn Solar OFF or Standby — prevents cold‑roof water
  • Check roof sensor health — avoid false heating calls
  • Disable boost/extended heat — unnecessary in winter

 

🔥 5. Heat Pump Winter Logic

  • Disable heating unless requested — default OFF
  • If heating ON: daytime only — prevents overnight run
  • Lower setpoint by 2–4°C — reduces energy use

 

💧 6. Anti‑Stagnation Cycles

  • Enable short burst cycles — 5–10 mins every 24–48 hrs
  • Low RPM only — just enough to move water
  • Independent of main schedule — runs even when filtration is off

 

🌡️ 7. Sensor Calibration & Drift

  • Check water temp sensor — cold weather drift
  • Check roof sensor — solar lockout accuracy
  • Check pipe sensor — heating logic stability

 

🧊 8. Freeze Protection (If Supported)

  • Enable freeze protection — 2–4°C
  • Set low‑RPM freeze circulation
  • Disable heating during freeze events

 

📣 9. Customer Notes (Prevent Call‑Backs)

  • Explain reduced run times
  • Explain solar/heating lockout
  • Explain low RPM operation

 

✔️ Installer Quick Summary

  • Winter Mode ON
  • Filtration 2–4 hrs/day
  • Low RPM circulation
  • Solar OFF
  • Heating OFF or limited
  • Anti‑stagnation ON
  • Sensors checked
  • Customer informed